- Temperature Limits 400°F to 800°F/204°C to 425°C
- Pressure Limits
- Dynamic (wet): 300 psi(g)/20 bar(g) Static (wet and dry): 450 psi(g)/31 bar(g) Dynamic (dry): 15 psi(g)/1 bar(g)
- Speed Limits 5000fpm/25m/s
- Temperature Limits -330°F to 800°F/-280°C to 425°C
- Pressure Limits Vacuum to 360 psi(g)/25 bar(g)
- Speed Limits 10,000fpm/50m/s
- Temperature Limits -100°F to 800°F/-75°C to 425°C
- Pressure Limits Vacuum to 300 psi(g)/20 bar(g)
- Speed Limits 10,000fpm/50m/s
- Temperature Limits -100°F to 500°F/-75°C to 260°C
- Pressure Limits Vacuum to 300 psi(g)/20 bar(g)
- Speed Limits 5000fpm/25m/s
- Temperature Limits -100°F to 800°F/-75°C to 425°C
- Pressure Limits Vacuum to 300 psi(g)/20 bar(g)
- Speed Limits 5000fpm/25m/s
- Temperature Limits -100°F to 800°F/-75°C to 425°C
- Pressure Limits 300 psi(g)/20 bar(g)
- Speed Limits 5000fpm/25m/s
- Temperature Limits -320°F to ambient/-196°C to ambient
- Pressure Limits Vacuum to 100 psi(g)/7 bar(g)
- Speed Limits 10,000 rpm
- Temperature Limits -100°F to 800°F/-75°C to 425°C
- Pressure Limits
- Vacuum to 300 psi(g)/20 bar(g) (See Basic Pressure Ratings curve on Product Specification sheet.) DOUBLE-PLY: Vacuum to 600 psi(g)/42 bar(g) (Maximum pressure rating can vary; consult John Crane Engineering for maximum DOUBLE-PLY pressure rating for your specific application.)
- Speed Limits 10,000fpm/50m/s
- Other 1.5" to 4.33"/30mm to 110mm